Specifications
|
|
3350
|
5350
|
Size Range:
|
0.3 - 25.0μm
|
0.5 - 25.0μm
|
Standard Channel Sizes:
|
0.3, 0.5, 1.0, 3.0, 5.0, 10.0μm
|
0.5, 0.7, 1.0, 3.0, 5.0, 10.0μm
|
Optional Channel Sizes:
|
0.3, 0.5, 1.0, 5.0, 10.0, 25.0μm
|
0.5, 1.0, 3.0, 5.0, 10.0, 25.0μm
|
|
|
|
Flow Rate:
|
100.0 LPM (3.53 CFM)
|
Counting Efficiency:
|
3350, 50% @ 0.3μm; 100% @ sizes > 0.45μm; 5350, 50% @ 0.5μm; 100% @ sizes > 0.75μm Per JIS B 9921 and ISO 21501-4
|
Light Source:
|
Extreme Life Laser Diode Technology with >20-year Mean Time To Failure (MTTF)
|
Zero Count Level:
|
<1 count / 5 minutes (per JIS B 9921)
|
Concentration Limits:
|
400,000 Particles/ft3 (14,120,000/M3) @10% Coincidence Loss, Suitable for ISO classes 1 through 8 Cleanrooms
|
Calibration:
|
Meets ISO 21501-4 Calibration Standard
|
Count Modes:
|
Automatic, Manual, Beep, Concentration, Cumulative/Differential and Real Time (with LMSNet or LMS Express RT)
|
Data Storage:
|
3,000 Sample Records (Rotating Buffer), which includes particle and environmental data with locations and times
|
Communication Modes:
|
USB; Ethernet; RS-485; Secure Data Transfer to and Storage on USB Flash Drive
|
Supporting Software:
|
LMS XChange, LMS Express and Express RT; LMS Standard; LMS Pharma; CREWin
|
Environmental Sensors:
|
Optional (up to 4): Temperature/Relative Humidity, Air Velocity, Differential Pressure or others
|
Touch Screen Display:
|
5.7-inch (14.47 cm) color, 320x240
|
Location Labels:
|
Up to 400, based on Location Label Length
|
Printer:
|
Built-in Thermal Printer (non-printer model available)
|
Reports:
|
Pass/Fail Report Wizard for ISO-14644-1, EU GMP Annex 1 and FS-209 Report Formats
|
Alarm:
|
Integrated Alarm Buzzer and External Alarm Connector. Alarms on Counts, Low Battery, Sensor Failure
|
Enclosure:
|
Stainless Steel
|
Sample Output:
|
Internally filtered to HEPA standards (>99.997% @ 0.3μm)
|
Vacuum Source:
|
Internal Closed-loop Controlled Pump: allows the use of 3/8” ID Sample Tubing of up to 12 Meters (40 feet) @ 100 LPM
|
Power:
|
100-250 VAC, 47-63 Hz
|
Battery:
|
Li-Ion, Removable & Rechargeable; Typical Battery Operation ~4 hours*; Tyical Recharge Time ~4 hours
|
Dimensions:
|
14.65” (l) x 8” (w) x 10.4” (h) [37 x 20 x 26 cm]
|
Weight:
|
With Battery: 26 lbs (11.8 kg) Without Battery: 23 lbs (10.43 kg)
|
Languages:
|
English, Fran?ais, Deutsch, Italiano, Espa?ol
|
Environmental Conditions
|
Operating:
|
50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing
|
Storage:
|
14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing
|
Accessories
|
Included:
|
Operating Manual on CD; Isokinetic Sample Probe with Tripod and Tubing; Purge Filter; Power Cable and Spare Fuse; LMS XChange Software; Printer; Printer Paper
|
Optional:
|
Wireless Network Adapter; Removable Rechargeable Li-Ion Battery; Carrying Case with Wheels; Temperature/Relative Humidity Probe; Differential Pressure Probe; Intelligent Filter Scanning Probe; Air Velocity Probe; Spare Removable Rechargeable Li-Ion Battery; External Battery Charger; LMS Express, RT Software; LMS Pharma
Edition Software; LMS Standard Software; Validation Documentation; Printed Operating Manual; Cleanroom Cart
|